6tr oubleshoo ting, P.27 – Camco Amplifier User Manual

Page 29

Advertising
background image

6

TR

OUBLESHOO

TING

Operating Status

LED Sequence ( ) = flash, (__) = off

Description of repeated
sequences

Normal (no failure)

Permanently lit

Power Fail
(i.e. switch off)

Short 50 ms flash + 950 ms
pause

High Temperature
signal attenuation

750 ms flash + 250 ms pause

Over Temperature
main SMPS off

250 ms flash + 750 ms pause

DC
reason unknown

250 ms flash + 250 ms pause

DC
input-signal-faul

3 * flashing + 0.5 s pause

DC
fault in driver stage

4 * flashing + 0.5 s pause

DC
output stage defect

5 * flashing + 0.5 s pause

Output Stage Defect
without DC

6 * flashing + 0.5 s pause

Main SMPS off
(unless Hi Temp/Power Fail)

2 * flashing + 0.5 s pause

USER MANUAL
VORTEX 3 QUADRO

P.27

6. On LED Flashing Sequences

When switching on the amp the On LEDs flash twice accompanied by a flash of
Clip LEDs. This is normal for the ‘Start’ sequence of the VORTEX.

When switching off the amp the On LEDs flash several times followed by a
flash of Clip LEDs. This is normal for the ‘Shut Down’ sequence of the VORTEX.
(It is the same as the loss of the mains voltage.)

In the following table you will find the possible LED sequences of the On LEDs:

Examples of LED Sequences
LED sequence:

Ch:

Ch2:

Ch3:

Ch4:

Failure:

Ch: high temperature with signal attenuation
Ch2: normal operation
Ch3: normal operation
Ch4: normal operation

LED sequence:

Ch:

Ch2:

Ch3:

Ch4:

Failure:

Ch: DC, output stage defect
Ch2: main SMPS off
Ch3: main SMPS off
Ch4: main SMPS off