2.3
Checking the adjustment
In normal use with magazines in the gripper the functional LED has not to blink.
3
DIP-Switches
Parameter
Dip-Switch Position
Value
Remark to dead time
Inactive
15% if DIP 3 = ON
Double copy counting
Active
7% if DIP 3 = ON
Pulse
Counting signal output
Synchronous
Minimal
1%
Dead time
Maximal
Defined by DIP 1
Maximal
Sensitivity
Reduced
Signal from
synchronization sensor
Signal from magazin
Signal from magazin
Signal from magazin
15%
85%
100%
It is ok.
orange LED flashing: Position to fare away
green LED flashing: Position to close