2.3

Checking the adjustment

In normal use with magazines in the gripper the functional LED has not to blink.

3

DIP-Switches


Parameter

Dip-Switch Position

Value

Remark to dead time

Inactive

15% if DIP 3 = ON

Double copy counting

Active

7% if DIP 3 = ON

Pulse

Counting signal output

Synchronous

Minimal

1%

Dead time

Maximal

Defined by DIP 1

Maximal

Sensitivity

Reduced



Signal from
synchronization sensor

Signal from magazin

Signal from magazin

Signal from magazin

15%

85%

100%

It is ok.

orange LED flashing: Position to fare away

green LED flashing: Position to close

Advertising