4outputs and led indicators – Baumer BA Scatec2 Gripper User Manual

Page 9

Advertising
background image

20101215_Shortmanual_ScatecDCC_EN.doc

9/10

Baumer Electric AG

15.12.2010 / wej

Frauenfeld, Switzerland

Synchronization signal

Copies

1

2

3.

0

Counting
signal output

Double copy
counting

Out 1

Out 2

Out 1

Out 2

Out 1

Out 2

active

inactive

synchron

Pulse

Edge

LED

off

green

orange

red

Edge

LED

active

inactive

synchron

Pulse

Edge

LED

Orange as long the Scatec detects an edge

Functional
LED

off

off

green

orange

orange

off

Green: normal Situation
Orange: special setup via ScaDiag
Green blinking: position of magazines to close
Orange blinking: Position of magazines to fare away

LED / output signal

L

E

D

s

o

u

tp

u

ts

In case of too low supply voltage the functional and edge LED is orange

4

Outputs and LED indicators


Output 1: switches ON with 1 or 2 copies
Output 2 switches ON with more than 2 copies

Remark:
Output 1 and 2 will be updated with the next following pulse of the synchronization sensor if synchronous
counting signal output (DIP 2) is chosen.