6overview of spdus, Table of general information spdus, 2 table of parameter spdus – Baumer BA FADx14 IO User Manual

Page 15

Advertising
background image

BA_FADK14IO-Link_V01-02-11_EN.doc

15/18

Baumer Electric AG

04.12.2012

Frauenfeld, Switzerland

6

Overview of SPDUs

6.1

Table of General Information SPDUs

S

P

D

U

n

a

m

e

S

P

D

U

i

n

d

e

x

N

u

m

b

e

r

o

f

B

y

te

s

F

o

rm

a

t

R

a

n

g

e

o

f

v

a

lu

e

s

R

/W

C

o

m

m

e

n

ts

General information on sensors

Vendor Name

0X10

18

String

ASCII

R

“Baumer Electric AG“ for all sensors

Product Name

0X12

22

String

ASCII

R

Corresponds with Baumer article descrip-

tion

Product ID

0X13

8

String

ASCII

R

Corresponds with Baumer article number

Serial Number

0X15

4

String

ASCII

R

Baumer P-Code

Firmware Revision

0X17

8

String

ASCII

R

Baumer Firmware Revision

Application Specific

Name

0X18

8

-

-

R/W

8 Byte at customer disposal

6.2

Table of Parameter SPDUs

S

P

D

U

n

a

m

e

S

P

D

U

i

n

d

e

x

N

u

m

b

e

r

o

f

B

y

te

s

F

o

rm

a

t

R

a

n

g

e

o

f

v

a

lu

e

s

R

/W

C

o

m

m

e

n

ts

Measuring range and switching points

Switching points

work

0X40

4

Switching point A (HB, LB)

Switching point B (HB, LB)

500…4000

R/W Distance information on switching points

Switching points

interim

0X41

4

Switching point A (HB, LB)

Switching point B (HB, LB)

500…4000,

65535

R

Distance information on switching points

Measuring range

work

0X42

4

Measuring range limit A (HB, LB)

Measuring range limit B (HB, LB)

500…4000

R/W Distance information on measuring range

limits

Measuring range

interim

0X43

4

Measuring range limit A (HB, LB)

Measuring range limit B (HB, LB)

500…4000,

65535

R

Distance information on measuring range

limits

Sensor functions

Average

0X50

1

-

0,1,2,4,8,

16

R/W Number of measuring cycles across which

an average is formed.

Average value = 0 or 1: Average is

switched off.

Output function

switching output

0X62

1

0 = ON, if there is no valid signal

within MB

1 = Switching output defined by

switching points

2 = ON if signal falls below

excess gain signal threshold

0,1,2

R/W Indicates what function is available on the

output.

Nominal value

quality parameter

0X65

1

1..8

R/W Provided the internal quality parameter

drops below this threshold, the switching

output is set.

Quality parameter

0X66

1

1..8 or 255

R

Advertising