5.1.3.2 Example of Teaching an Object

The measuring range is to be taught for an object (characteristic curve 2).

Figure 3: Teaching characteristic measuring value curves


For an inverted characteristic curve (characteristic curve 3), the distance between the sensor and Measuring
range limit A
must exceed that to Measuring range limit B.

5.1.4

Error Handling

The taught measuring values lie closer together than is permitted by the learnable measuring range (20mm):

Error message: Interfering parameter (refer to: Table Fehler! Verweisquelle konnte nicht gefun-
den werden.
, Fault codes);

Interim register is set to FFFF FFFF hex;

The most recent valid values remain active.


The learned measuring value lies outside the original measuring range (measuring range on the specification
sheet):

Numerical teaching: Unable to write to Measuring range work; error message: Parameter value
out of range.
The most recent valid values remain active.