Baumer N 143 User Manual

Page 10

Advertising
background image

N 143

10 www.baumer.com

4.2.3. Readout device status „F“ (46h)

This command retrieves the device statuses Stat1, Stat2 together with error flags Err1, Err2. In case of error,
the check command “C” will come with an “e” in reply.

Example:

SOH Adr Cmd EOT CRC

Transmission

01h 20h 46h 04h 00h

SOH Adr Cmd Stat1 Stat2 Err1 Err2 EOT CRC

Response

01h 20h 46h 80h 80h 80h 80h

04h

4Bh


Stat1: 1 0 0 0 0 0 0 X

┬ ─────┬───── ┬
│ │ └──

Motor on standby for transmission

│ │

0 = No motor start signal. SPA does not transmit any IR data

│ │

1 = Motor start signal.

│ │ Interactive mode (motor start by broadcast command):
│ │ SPA is enabled for alignment by power tool, however so far there
│ │ has not been any IR data transmission. LED is flashing slowly.
│ │ Motor start is enabled using the key.
│ │ Direct mode (motor start signal via device address):
│ │ SPA is enabled for alignment by power tool, IR data are being
│ │ transmitted. LED is flashing.
│ └───────── reserved
└──────────────── ever 1

Stat2: 1 0 0 0 0 0 0 X

┬ ─────┬───── ┬
│ │ └── 1 = SPA is transmitting motor commands. During motor start enable.
│ │ the bit will remain set. LED is flashing.
│ └───────── reserved
└──────────────── ever 1

Err1: 1 0 0 0 0 0 X X

┬ ──┬── ┬ ┬ ┬ ┬
│ │ │ │ │ └── 1 = Err 8 - target > MAX limit (motor does not start)
│ │ │ │ └──── 1 = Err 9 - target < MIN limit (motor does not start)
│ │ │ └────── reserved
│ │ └──────── reserved
│ └──────────── reserved
└──────────────── ever 1

Err2: 1 0 0 X 0 0 X X

┬ ┬ ┬ ┬ ┬ ┬ ┬ ┬
│ │ │ │ │ │ │ └── 1 = Err 1 - MAX limit hurt
│ │ │ │ │ │ └──── 1 = Err 2 - MIN limit hurt
│ │ │ │ │ └────── reserved
│ │ │ │ └──────── reserved
│ │ │ └────────── 1 = Err 5 – target window not attained
│ │ └──────────── reserved
│ └────────────── reserved
└──────────────── ever 1