N 143 – Baumer N 143 User Manual

Page 15

Advertising
background image

N 143

www.baumer.com

15

4.2.10. Indicate optional number sequence in the lower line of the display „u“ (75h)

The command writes a 6-digit number sequence in the lower display line. The sequence is indicated without dot
respectively comma. Leading zeros as well as both direction arrows are hidden. The upper line is still indicating
the current target or number sequence.
The number sequence will be displayed until any command except „t“, „u“ or „R“ is received via interface.
The number will be retained even after power failure.

Example: (number sequence = 123456)

SOH Adr Cmd

Number sequence = 123456

EOT CRC

Transmisison

01h 20h 75h 31h 32h 33h 34h 35h 36h

04h BCh

SOH Adr Cmd

Number sequence = 123456

EOT CRC

Transmission

01h 20h 75h 31h 32h 33h 34h 35h 36h

04h BCh


Note:
Combining the commands „t“ and „u“ enables a 12-digit number in the display. Neither number sequence nor
tool number will be saved.