Significance of parameter „m – Baumer N 143 User Manual

Page 19

Advertising
background image

N 143

www.baumer.com

19

Note: Only the bits marked ‘X’ permit alteration. The permanent values ‚1’ and ‚0’ must remain unchanged since
otherwise control characters (characters < 20h) might be created which are not allowed in ASCII protocols.

Example 1: Read bit parameter (Data 1 to Data 3 = 80h; Data 4 to Data 5 = 30h)

SOH Adr Cmd EOT CRC

Transmission

01h 20h 6Dh 04h 56h

bit parameter default


Example 2: Write bit parameter (key assignment = down; motor direction = down)

SOH Adr Cmd Data1 Data2 Data3 Data4 Data5 EOT CRC

Transmission

01h 20h 6Dh 81h 84h 80h 30h 30h

04h

92h

SOH Adr Cmd Data1 Data2 Data3 Data4 Data5 EOT CRC

Response

01h 20h 6Dh 81h 84h 80h 30h 30h

04h

92h


Significance of parameter „m“


Key assignment
This parameter assigns a specific direction of rotation to a certain key. For mounting option “keypad below dis-
play” and the related default parameters applies the following:

0 = Up

left/right key actuation = shaft rotation ccw/cw, counting mode UP/DOWN

1 = Down

left/right key actuation = shaft rotation cw/ccw, counting mode UP/DOWN


Motor’s direction of rotation
The parameter “motor direction of rotation” enables inversion of the two output signals for motor ccw (pin B) and
motor cw (pin C) provided at the motor cable. The inversion is only effective with automated positioning. Manual
positioning operations by buttons remain unaffected.

0 = Up

Standard direction of rotation

1 = Down

Inverted direction of rotation


Shaft type
The shaft type parameter assigns the shaft type.
Some applications may call for different handling of radially and axially operated shafts what is already taken
into consideration when utilizing the Baumer IVO master. For example, only specific shafts are to be indicated in
DIM mode. When utilizing other masters (PLC or PC), this parameter may serve for general assignments.

0 = R

Radial type

1 = A

Axial type


Group
Parameter to classify groups. Individual SPAs can be assigned to one out of 8 individual groups to be started in
successive order (command „D“) to prevent collisions.

0 = Group 1
1 = Group 2
: :
7 = Group 8

Start signal for the respective group. Start command „D“ must include the related group num-
ber.


To make best use of the memory capacity, several parameters are compiled for a packed transmission. Pa-
rameter encoding is as follows:
Note: Only the bits marked ‘X’ permit alteration. The permanent values ‚1’ and ‚0’ must remain unchanged since
otherwise control characters (characters < 20h) might be created which are not allowed in ASCII protocols.

SOH Adr Cmd Data1 Data2 Data3 Data4 Data5 EOT CRC

Response

01h 20h 6Dh 80h 80h 80h 30h 30h

04h

F2h