Command explanations, General, Operating commands – Baumer N 143 User Manual

Page 7

Advertising
background image

N 143

www.baumer.com

7

4. Command

explanations

4.1. General

The following describes the individual interface commands which are broken down into the four groups below:

-

operating commands [ commands required during operation ]

-

parameter commands [ commands for SPA parameterization ]

-

address commands

[ commands to indicate or alter the device identifier (address)]

-

specific commands

[ commands for specific functionalities (device reset, version number readout]


The following abbreviations are applied:

SOH = Start of heading (header token)
EOT

= End of transmission (footer token)

Adr

= Device address, including offset 20h

Cmd

= Command

SCmd = Sub command
Data

= data transmitted or received

CRC = Cyclic redundancy check

4.2. Operating commands

Command

code

Data length

in bytes

read

write

Broad-

cast

Saved in

EEPROM

Significance

C (43h)

3 / 11

X

-

-

-

Check if current value = target

D (44h)

1

X

X

X

-

Start motor

F (46h)

4

X

-

-

-

Readout device status and error

R (52h)

6

X

-

-

-

Read current value

S (53h)

8

X

X

-

X

Read/write target

U (55h)

6

X

X

-

-

Offset

V (56h)

2

X

X

X

X

Read / write profile number

t (74h)

6

-

X

-

-

Transmit tool number

u (75h)

6

-

X

-

-

Transmit any optional number sequence

Z (5Ah)

6

X

X

X

X

Set preset


4.2.1. Check Position „C“ (43h)

This command provides the alignment status of target versus current value. If the current value is within the tar-
get tolerance window, the response will be „o“ (6Fh) for OK together with the current profile number. If the cur-
rent value is outside the tolerances, „x“ (78H) followed by the current profile number will be replied. In case of
any error occurred at the SPA the response will be “e” together with the current profile number.

Example: (active profile number = 05)

SOH Adr Cmd EOT CRC

Transmission

01h 20h 43h 04h 0Ah

Response if current value within tolerance window: (Status = 6Fh = „o“)

SOH Adr Cmd Stat. Profile no.=05 EOT CRC

Response

01h 20h 43h 6Fh 30h

35h 04h A5h

Response in case of current value outside tolerance window: (Status = 78h = „x“)

SOH Adr Cmd Stat. Profile no.=05 EOT CRC

Response

01h 20h 43h 78h 30h

35h 04h 1D


Following status parameters are available:

Status

Significance

o (6Fh)

Current value = target

x (78h)

Current value ≠ target

e (65h)

SPA error