7.2 Attribute 2: Transparent transfer of a SPA command

Class

Instance Attribute Access Rule


Name

DeviceNet
Data type

Default
Value

100 1

2

Transparent
Transfer
Service Code
0x32
(Vendorspecific)

Transparent transfer of SPA command

ARRAY[16]
of USINT


This object is for transparent transfer of all commands to the spindle position displays (SPA) utilizing the
vendor specific service Code 0x32.

Basically there is a transparent transfer of all commands under codes „A“...“z“ from DeviceNet Master to SPA
and vice-versa what enables addressing the SPAs individually or collectively by broadcast command. The
gateway does not verify whether a registered SPA is connected or not, neither the command code is verified.

The gateway replies to every command received by the DeviceNet-Master (PLC).

Response is by

transparent transfer of the SPA reply, if an individual SPA was addressed and duly replied

an abort message if the addressed SPA did not reply within the timeout window (approx. 100 ms)


Any timeout administered by the DeviceNet Master for monitoring of gateway reply should not be less than
400 ms.
The DeviceNet Master transmits to GK473 the transmission data within the limits SOH and EOT out of the
complete command to the addressed spindle position display (SPA). Length is always 16 bytes since digits
not utilized are filled up with 0.

Example: Programming the target (profile no = 17; target = -12,50; SPA identifier 0)

SOH

Adr

Cmd Profile no. = 17

Target = -12,50

EOT

CRC

Transmission

01h

20h

53h

31h

37h

2Dh

30h

31h

32h

35h

30h

04h

FBh



In the other direction (responding SPA) start and stop token as well as CRC byte are taken out of the RS485
message which in its remaining content is transferred unchanged into the data block of a DeviceNet message
so that it will be available at the PLC as consistent input data.

Example: Programming the target (profile no = 17; target = -12,50; SPA identifier 0)

SOH

Adr

Cmd Profile no. = 17

Target = -12,50

EOT

CRC

Response

01h

20h

53h

31h

37h

2Dh

30h

31h

32h

35h

30h

04h

FBh




For details regarding content and format of SPA commands please refer to the respective user
manual.