Baumer GK473 User Manual

Page 19

Advertising
background image

Manual_GK473_DeviceNet_EN.doc

19/31

Baumer IVO GmbH & Co. KG

04.05.11

Villingen-Schwenningen,

Germany

Batched information : GK473 class Instance Attribute 3..7

These objects are for convenient monitoring of the RS485 sub bus state and consequently the status of all
spindle position displays.
Prior condition of updated data is active Auto Scan SPA what means cyclic scanning of the RS485 sub bus.
Any change of state is saved in the GK473 memory for optional read-in into the PLC by Explicit Message, I/O
Poll or Change of State (COS).


7.3 Attribute 3: RS485 Sub-bus, full SPA status information

Class

Instance Attribute Access Rule


Name

DeviceNet
Data type

Default
Value

100

1

3

Get

RS485 sub-bus, full SPA status information

ARRAY[48]
of USINT



Output are 48 Bytes indicating the complete present status of the spindle position displays (SPAs) on the
RS485 sub-bus.
SPA identifiers and the respective states provide the following binary codes:



The data packet comprises the following information:
Byte 0..15 “SPA not in position”

Byte 16..31 “SPA in error state”

Byte 32..47 “SPA in timeout state”



Example below:
SPA with identifiers 1,2,7 und 30 are not in position

SPA with identifer 5 is in error state (no motor supply)

SPA with identifier 58 is in timeout state (cable break, no reply)