Indoor unit installation, Attention – FRIGIDAIRE FRS123LS1 User Manual

Page 12

Advertising
background image

Attention

Piping and wrapping

1. Bundle the tubing, connecting

cable, and drain hose with tape

2. Because the condensed water

from rear of the indoor unit is
gathered in ponding box and is

anything else in the box.

1. Connect the indoor unit first, then the outdoor unit.
2. Do not allow the piping to let out from the back of the indoor unit.
3. Be careful not to let the drain hose slack.

5. Be sure that the drain hose is located at the lowest side of the bundle. Locating

6. Never intercross nor intertwist the power wire with any other wiring.
7. Run the drain hose sloped downward to drain out the condensed water

smoothly.

Cushioning
material

3. Piping can easily be made by

lifting the indoor unit with a
cushioning material between the
indoor unit and the wall. Get it
out after finish piping.

4. Push the lower part of the indoor

unit up on the wall, Then move
the indoor unit from side to side,
up and down to check if it is
hooked securely.

Indoor unit installation

Indoor unit

Cable

Ponding
box

Pipe room

Wrapping
belt

Drain hose

Connective
pipe

securely and evenly as shown
in the sideward figure.

piped out of room, do not put

connection

at the upper side may cause drain pan to overflow inside the unit.

4. Both of the auxiliary piping should be heat insulation.

14