Refrigerant piping connection, Flaring work – FRIGIDAIRE FRS123LS1 User Manual

Page 16

Advertising
background image

4. Flaring work.

die in the dimension shown in
the table below.

OUTER

Connection Adjustment
1. Align the pipes to be connected.

OUTER

TIGHTENING

Caution: Excessive twisting may
break the nut, depending on the
installation conditions.

Refrigerant piping connection

Bar

pipe

Handle

Clamp
handle

Yoke

Red arrow mark

Flare

nut

Pipings

Indoor unit
tubing

Copper

A (inch)

Max.

Min.

DIAMETER (inch)

0.051

0.063

0.071

0.095

0.028

0.039

0.039

0.087

2. Screw the flare nut with your

fingers, and then tighten it with
a spanner and torque wrench,
as shown in the following figure.

ADDITIONAL TIGHTENING

DIAMETER (inch)

Firmly hold copper pipe in a

1/4

3/8

1/2

5/8

1/4

3/8

1/2

5/8

TORQUE

TORQUE (lbf.in)

139

174

260

304

434

477

651

694

(lbf.in)

18