Electrical work – FRIGIDAIRE FRS123LS1 User Manual

Page 20

Advertising
background image

1. Remove the electrical control

board cover from the outdoor unit
by loosening the screw.

2. Connect the connective cables to

the terminals as identified with
their respective matched numbers
on the terminal block of indoor
and outdoor units. The connective
cable to power supply shall be
approved polychloroprene
sheathed flexible cord

.

3. Secure the cable onto the control

board with the cord clamp.

4. To prevent the ingress of water,

cable as illustrated in the
installation diagram of indoor and
outdoor units.

5. Insulate unused cords (conductors)

Connect the cable to the outdoor unit

Screw

Cover

Electrical work

(Heating and cooling model)

(Heating and cooling model)

"Cable D”

"Cable F”

"Cable E”

or

form a loop of the connective

with PVC-tape. Process them so
they could not touch any electrical
or metal parts.

1.57"

0.39"

Code wire

Code wire

Code wire

Code wire

1.57"

1.57"

1.57"

0.39"

0.39"

0.39"

< 12000 btu's CABLE

< 12000 btu's CABLE (Cooling model)

> 12000 btu's CABLE

22