Compaq PROLIANT ML370 User Manual

Page 78

Advertising
background image

3-24 Compaq ProLiant ML370 Maintenance and Service Guide

Table 3-2
POST Error Messages

continued

Error Code

Audible Beeps

Probable Source of Problem

Recommended Action

1794 - Drive Array—
Array Accelerator
Battery Charge Low.
Array Accelerator is
temporarily disabled.
Array Accelerator will
be re-enabled when
battery reaches full
charge.

None

This is a warning that the battery
charge is below 75%.
Posted-writes are disabled.

Replace the Array Accelerator
board if batteries do not
recharge within 36 power-on
hours.

1795 - Drive Array—
Array Accelerator
Configuration Error.

Data does not
correspond to this
drive array. Array
Accelerator is
temporarily disabled.

None

This indicates that while the
system was in use, power was
interrupted while data was in the
Array Accelerator memory.

The data stored in the Array
Accelerator does not correspond
to this drive array.

Match the Array Accelerator to
the correct drive array, or run
the System Configuration Utility
to clear the data in the Array
Accelerator.

1796 - Drive Array—
Array Accelerator Not
Responding.

Array Accelerator is
temporarily disabled.

None

Array Accelerator is defective or
has been removed.

1.

Check that the Array

Accelerator is properly
seated.

2.

Run System Configuration

Utility to reconfigure the
Compaq IDA-2 without the
Array Accelerator.