1200-1299, Modem Communications Test Error Codes

The 1200 series of diagnostic error codes identifies failures with the modem.

Table 3-10

Modem Communications Test Error Codes

Error Code

Description

Recommended Action

1201-xx

Modem internal loopback test
failed.

1202-xx

Modem time-out test failed.

1203-xx

Modem external termination test
failed.

1204-xx

Modem auto originate test failed.

1206-xx

Dial multi-frequency tone test
failed.

1210-xx

Modem direct connect test failed.

1.

Refer to the modem documentation for correct

setup procedures and retest.

2.

Check the modem line and retest.

3.

Replace the modem and retest.

6000-6099, Compaq NIC Boards Test Error Codes

The 6000 series of diagnostic error codes identifies failures with various Compaq Network
Interface Controllers.

Table 3-11

Compaq Network Interface Boards Test Error Codes

Error Code

Description

Recommended Action

6000-xx

Network card ID failed.

6001-xx

Network card setup failed.

6002-xx

Network card transmit failed.

6014-xx

Network card configuration failed.

6016-xx

Network card reset failed.

6028-xx

Network card internal failed.

6029-xx

Network card external failed.

6089-xx

Network card open failed.

6090-xx

Network card initialization failed.

6091-xx

Network card internal loopback failed.

6092-xx

Network card external loopback failed.

1.

Check the controller installation in the slot.

2.

Check the interrupt type and the number

setting.

3.

Check the media connection at the

controller and Multistation Access Unit
(MAU).

4.

Check the media speed (4/16) and type

Unshielded Twisted Pair/Shielded Twisted
Pair (UTP/STP) settings.

5.

Check the MAU, cabling, or other network

components.

6.

Replace the controller.

Advertising