3-40 Compaq ProLiant ML370 Maintenance and Service Guide

Table 3-16
ADU Diagnostic Messages

continued

Message

Description

Recommended Action

Drive (bay) X is a
replacement
drive marked OK

This drive has been replaced and
marked OK by the firmware. This
may occur if a drive has an
intermittent failure (for example, if a
drive has previously failed, and then
when ADU is run, the drive starts
working again).

Replace the drive.

Drive (bay) X is
failed

The indicated physical drive has
failed.

Replace the drive.

Drive (bay) X is
undergoing drive
recovery

This drive is being rebuilt from the
corresponding mirror or parity data.

Normal operations should resume.

Drive (bay) X
needs replacing

The 210-megabyte hard drive has
firmware version 2.30 or 2.31.

Replace the drive.

Drive (bay) X
upload code not
readable

An error occurred while ADU was
trying to read the upload code
information from this drive.

If there were multiple errors, this drive may
need to be replaced.

Drive (bay) X
was
inadvertently
replaced

The physical drive was incorrectly
replaced after another drive failed.

Replace the drive that was incorrectly replaced
and replace the original drive that failed. Do not
run the System Configuration Utility and try to
reconfigure; data will be lost.

Drive Monitoring
features are
unobtainable

ADU unable to get monitor and
performance data due to fatal
command problem such as drive
time-out, or unable to get data
because these features are not
supported on the controller.

Check for other errors (time-outs, and so on). If
no other errors occur, upgrade the firmware to a
version that supports monitor and performance,
if desired.

Drive Monitoring
is NOT enabled
for SCSI Port x
Drive ID x

The monitor and performance
features have not been enabled on
this drive.

Run the System Configuration Utility to initialize
the monitor and performance features.

Drive time-out
occurred on
physical drive
bay X

ADU issued a command to a physical
drive and the command was never
acknowledged.

The drive or cable may be bad. Check the other
error messages on the Diagnostics screen to
determine resolution.

Drive X indicates
position Y

Message indicates physical drive that
appears to be scrambled or in a drive
bay other than the one for which it
was originally configured.

Examine the graphical drive representation on
ADU to determine proper drive locations.
Remove drive X and place it in drive position Y.
Rearrange the drives according to the ADU
instructions.

Duplicate write
memory error

Data could not be written to the Array
Accelerator board in duplicate due to
the detection of parity errors. This is
not a data loss situation.

Replace the Array Accelerator board.

continued