100˚199, primary processor test error codes, 199, primary processor test error codes -27, 199, primary processor test error codes – Compaq PROLIANT ML370 User Manual

Page 81

Advertising
background image

Diagnostics and Troubleshooting 3-27

100-199, Primary Processor Test Error Codes

The 100 series of diagnostic error codes identifies failures with processor and system board
functions generated by Compaq Server Diagnostics.

Table 3-3

Primary Processor Test Error Codes

Error Code

Description

Recommended Action

101-xx

CPU test failed

Replace the processor board and retest.

103-xx

DMA page registers test failed

104-xx

Interrupt controller master test
failed

105-xx

Port 61 error

106-xx

Keyboard controller self-test failed

Replace the processor board and retest.

107-xx

CMOS RAM test failed

108-xx

CMOS interrupt test failed

109-xx

CMOS clock load data test failed

1.

Replace the battery/clock module and retest.

2.

Replace the system board and retest.

110-xx

Programmable timer load data test
failed

111-xx

Refresh detect test failed

113-xx

Protected mode test failed

Replace the processor board and retest.

114-xx

Speaker test failed

1.

Verify the speaker connection and retest.

2.

Replace the speaker and retest.

3.

Replace the system board and retest.

116-xx

Cache test failed

Replace the system board and retest.

122-xx

Multiprocessor Dispatch test failed

123-xx

Interprocessor Communication
test failed

1.

Check the system configuration and retest.

2.

Replace the processor board and retest.

3.

Replace the system board and retest.

199-xx

Installed devices test failed

1.

Check the system configuration and retest.

2.

Verify cable connections and retest.

3.

Check switch and/or jumper settings and retest.

4.

Run the Configuration Utility and retest.

5.

Replace the processor board and retest.

6.

Replace the system board and retest.