Enclosure interior – Chicago Pneumatic CS7000 User Manual

Page 22

Advertising
background image

6159939130 CS7000 Controller Hardware Overview Manual

Page 2-6

39-30-41365

I/O Connector

The 19-position remote I/O connector provides the interface between external control/monitoring
devices and the internal control electronics. CP techmotive accessories, such as socketrays, are
connected here.

The mating connector for this port is a 14-shell, 19-pin, strain relief (SR) connector
(part number 23-10-5200). The mating connector enables connection of your own remote control
and/or monitoring devices, such as external annunciator lamps or remote cycle-on contacts. Refer to
I/O Wiring in Chapter 3. Installing the CS7000 Controller for pinout details.

Enclosure Interior

The enclosure interior for the CS7000 Controller includes the following components and sub-
components:

Sub-panel, that includes:

Disconnect switch

Power supply (24 VDC)

Circuit breaker/ Fuses

Ground fault circuit interrupter (GFCI)

Backplane, that includes:

Address switch

DCM fuse (internal DCM power)

I/O power (24 VDC) fuses

TCM, that includes:

DCM control card

Servo

Communications Control Module (CCM) optionally

See Figure 2-5 on page 2-7 and Figure 2-6 on page 2-8.

Advertising