Chapter 3. Installing the CS7000 Controller

____________________________________________________________________________________________
December 2005

Page 3-7

A remote input circuit schematic is shown in Figure 3-2.

Figure 3-2. Remote Input Circuit Schematics

To ensure that you operate the fastening system properly, refer to Table 3-2 for input requirements.

Table 3-2.

Guidelines for Proper Operation of the Controller I/O Signals

Discrete Inputs

Unit

Highest permissible input voltage

30 V

Lowest permissible input voltage

-5 V

Minimum guaranteed input activation

10 V

Maximum guaranteed input deactivation

1.5 V

Discrete outputs

Unit

Maximum output current

360 mA

Maximum voltage

28 Volts DC

NOTE:

????

Installing J8 (supplied 24 VDC to “output-common-bus” and
each of the individual output (J12 and J13 jumpers) eliminates
the need to wire 24VDC to the output terminals for sourcing.