Troubleshooting

Volume (xx:yy:zzz) is

currently in state

“STATE”

Lists the current state of the specified virtual disk
when it is not optimal. The state may include:

• INACTIVE: The virtual disk is inactive, possibly

foreign, or could be in any one of the states
mentioned below.

• DEGRADED: The virtual disk is in a degraded state

and has lost redundancy.

• RESYNCING: The virtual disk is degraded and

currently rebuilding.

• FAILED: The virtual disk has an error and is in a

failed state.

• MISSING: The virtual disk is no longer present

though a record of it remains.

• UNKNOWN: The virtual disk has an error that is

not defined by the previous errors.

Device not available

at HBA n,HDL n, LUN

Device may not be ready at this time. The device will
be retried. If the problem persists, restart your
system.

ERROR! Device is not

responding to Read

Capacity

The device did not respond to a read capacity
command. Contact Dell.

Please wait, spinning

up the boot device!

The boot device was inactive, and is now spinning
up.

Devices in the

process of spinning

up

One or more devices were inactive and are now
spinning up.

nn drives are

reported, BIOS memory

allocation is full!

The reported drives consumed all of the available
memory, no more memory can be allocated.

Failed to add device,

too many devices!

Could not allocate resources for additional devices.

Table 7-4.

BIOS Error Messages (continued)

Message

Meaning

PERC H200.book Page 66 Tuesday, July 13, 2010 4:15 PM