Dell PowerEdge RAID Controller H200 User Manual

Page 68

Advertising
background image

68

Troubleshooting

MPT BIOS Fault xxh

encountered at

adapter PCI (xxh,

xxh, xxh)

Fault 01: No I/O port assigned to the adapter.

Fault 02: A MPT firmware fault occurred.

Fault 03: No image for firmware download boot.

Fault 04: Firmware download boot checksum error.

Fault 05: IOC hardware error.

Fault 06: MPT firmware communication error.

Fault 07: PCI bus master error.

Fault 08: String image (messages) not found.

Fault 09: String memory allocation failed.

Fault 0A: String upload failed.

Fault 0B: String image was invalid.

Fault 0C: Unsupported IOC configuration.

Fault 0D: Timeout waiting for IOC to reply.

Fault 0E: Transmit doorbell handshake error.

Fault 0F: Receive doorbell handshake error.

Fault 10: No memory mapped I/O address assigned.

Fault 11: IOC facts failure.

Fault 12: IOC initialization failure.

Fault 13: Port enable failure.

MPT BIOS Fault xxh

encountered at

adapter PCI (xxh,

xxh, xxh)

When xxh is 02 or 11, a 4-digit hexadecimal fault
value may be displayed with this message. Ensure
that you make a note of this value and contact
technical support for assistance.

Table 7-4.

BIOS Error Messages (continued)

Message

Meaning

PERC H200.book Page 68 Tuesday, July 13, 2010 4:15 PM

Advertising