Reset error & manufacturer identification, Device identification, Hardware version – CH Tech EM405D User Manual

Page 30: Firmware version, Figure 7. em405d registers

Advertising
background image

24

Reg. 00

Reset Error & Manufacturer Identification

Byte

1

0

Bit

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

Write

RERR

-

-

-

Read Only

Read

RERR

0

0

0

MID

RERR  Reset Error (writing a 1 clears the error condition)

1

MID  Manufacturer ID (always FC1

16

- C&H)

Notes:

1. This bit is set if a command error occurs. If an error exists, only reads or writes to this register are

allowed. The RERR bit must be cleared by writing a 1 to this bit before normal command operation
will resume. See 4.3.1 for further details.



Reg. 02

Device Identification

Byte

3

2

Bit

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

Write

-

-

-

-

Read Only

Read

ETH

0

0

0

DID

ETH  Ethernet Type (0 = wired, 1 = wireless (Wi-Fi))

DID  Device ID (always FDB

16

- EM405D)



Reg. 04

Hardware Version

Byte

5

4

Bit

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

Write

Read Only

Read Only

Read

HW Major

HW Minor

HW Major  Major Version Level of EM405D Hardware

HW Minor  Minor Version Level of EM405D Hardware




Reg. 06

Firmware Version

Byte

7

6

Bit

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

Write

Read Only

Read Only

Read

FW Major

FW Minor

FW Major  Major Version Level of EM405D Firmware

FW Minor  Minor Version Level of EM405D Firmware


Figure 7. EM405D Registers

Advertising