CH Tech EM405D User Manual

Page 9

Advertising
background image

3

1.3 Electrical

The EM405D only requires a +12V DC power input. The +12V input is internally converted to
the +3.3V power required by the carrier and the +5V, +12V, and -12V power required by the M-
modules. A maximum of 30 watts is required to support the carrier and two M-modules
operating at the maximum allowed power consumption. The maximum allowed power
consumption for each M-module is 1A of +5V and 200ma each of +12V and -12V. The
EM405D uses power-off resetable fuses on the incoming +12V supply. If a fault occurs, power
must be removed before the fuse will reset. The fuse is rated at 5 amps.

1.4 Mechanical

The EM405D is contained in a metal chassis with an outside dimension of 5.6 inches wide by 8.5
inches deep by 1.5 inches high. A variable speed fan provides forced air for cooling the M-
modules. The unit weighs approximately 1.7 lbs with no M-modules installed.

1.5 Environmental

The environmental specifications of the module are:

Operating Temperature:

0

C to +60

C*

Storage Temperature:

-40

C to +75

C

Humidity:

<95% without condensation


* The forced air cooling is designed to allow a maximum 20

C temperature rise for installed M-

modules. In other words, with two M-modules operating at full dissipation, the M-modules’
temperature can only be maintained within 20

C of the ambient air inlet temperature.

Installed M/MAs may differ in environmental specification. Refer to each individual M/MA’s
documentation for information.


1.6 Bus Compliance

The module complies with the ANSI/VITA 12-1996 Specification for single or double-wide M-
Modules and the MA-Module trigger signal extension.

Addressing:

A08 only (extended addressing not supported)

Data:

D16 only

Interrupts:

not supported

DMA:

not supported

Triggers:

Trig A and Trig B Input/Output

Manufacturer ID:

0FC1

16

Model Number:

0FDB

16