Reset & trigger control, Fan control & temperature status, Figure 7. em405d registers (continued) – CH Tech EM405D User Manual

Page 31

Advertising
background image

25

Reg. 08

Reset & Trigger Control

Byte

9

8

Bit

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

Write

RSTB

RSTA

TLVL

TIMP

BTBD

BTBM

BTAD

BTAM

ATBD

ATBM

ATAD

ATAM

Read

RSTB

RSTA

TLVL

TIMP

BTBD

BTBM

BTAD

BTAM

ATBD

ATBM

ATAD

ATAM

RSTB  Reset M-module B (0 = normal, 1 = reset)

1

RSTA  Reset M-module A (0 = normal, 1 = reset)

1

TLVL  External Trigger Input Threshold Level (0 = +2.5V, 1 = +1.4V)

TIMP  External Trigger Input Impedance (0 = high (>100K

), 1 = 50

)

BTBD  Module B Trigger B Direction (0 = input, 1 = output)

2

BTBM  Module B Trigger B Mode

0 0 Disabled

0 1 to/from External Trigger

1 0 to/from Module A Trigger A

1 1 to/from Module A Trigger B

BTAD  Module B Trigger A Direction (0 = input, 1 = output)

2

BTAM  Module B Trigger A Mode

0 0 Disabled

0 1 to/from External Trigger

1 0 to/from Module A Trigger A

1 1 to/from Module A Trigger B

ATBD  Module A Trigger B Direction (0 = input, 1 = output)

2

ATBM  Module A Trigger B Mode

0 0 Disabled

0 1 to/from External Trigger

1 0 to/from Module B Trigger A

1 1 to/from Module B Trigger B

ATAD  Module A Trigger A Direction (0 = input, 1 = output)

2

ATAM  Module A Trigger A Mode

0 0 Disabled

0 1 to/from External Trigger

1 0 to/from Module B Trigger A

1 1 to/from Module B Trigger B

Notes:

1. This bit must be cleared by user software to return the M-module to normal operation. The reset bit

need only be set to a 1 for a minimum of 1

s to properly reset an M-module.

2. The direction is with respect to the M-module specified. For intermodule triggers, the M-module

trigger directions must be set opposite one another for proper operation.



Reg. 0A

Fan Control & Temperature Status

Byte

B

A

Bit

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

Write

VARF

-

-

-

Read Only

Read

VARF

0

0

0

TEMP

VARF  Variable Speed Fan (0 = variable, 1 = full ON)

TEMP  Enclosure Temperature (°C = (TEMP – 281) / 4.6)



Figure 7. EM405D Registers (continued)