APPENDIX B – WIRED ETHERNET DEFAULT SETTINGS

The Ethernet interface device on the wired version of the EM405D contains many configurable
settings that allow it to be used in a large number of applications. Many of these settings must be
set to certain values in order for the EM405D to operate normally. Other settings are not
applicable to the EM405D. When the user tries to configure the network settings via the web-
interface or the telnet interface, he/she will see options to change many of these settings.
Changing some of these may make the EM405D inoperable. For this reason, it is highly
recommended that the user does not change any settings other than the following:

IP Address

Subnet Mask

Gateway Address


Table B-1 lists the various settings and their default values as set my C&H during manufacturing
of the EM405D. If the carrier fails to operate, verify that these settings are set to their default
values prior to calling C&H for technical support. Settings that are emphasized in bold italics
are required settings that if changed will render the carrier inoperable.

Table B-1. Ethernet Interface Default Settings.

Server Properties

IP Address

0.0.0.0

Subnet Mask

0.0.0.0

Gateway Address

0.0.0.0

Serial Settings

Baud Rate

921600

Data bits

8

Parity

None

Stop bits

1

Flow control

None

UDP Datagram Mode

Datagram Mode

False

Datagram Type

N/A

Passive Connection

Password Required

False

Port Password

N/A

Accept Passive Connection

Yes

Local Port**

10001

Auto Increment Source Port

False

** The EM405D will operate with any port number; however, many software applications
expect the port to be set to the default as shown in this table. Changing the port number will

not render the EM405D inoperable but may render these software applications inoperable

.