Example of a syslog message, Verification example for link noise monitoring – Cisco 10000 User Manual

Page 367

Advertising
background image

17-5

Cisco 10000 Series Router Software Configuration Guide

OL-2226-23

Chapter 17 Configuring Link Noise Monitoring

About Link Noise Monitoring

Example of LNM Configuration on a Shared Port Adapter

Example 2

shows how to configure the LNM feature ona 2-port Channelized OC12/DS0 SPA.

Example 2

Sample Output of LNM Configuration on a SPA

Router# configure terminal

Router(config)# controller soNET 5/1/0

Router(config-controller)# framing sonet

Router(config-controller)# clock source internal

Router(config-controller)# sts-1 1

Router (config-ctrlr-sts1)# mode ct3

Router (config-ctrlr-sts1)# t1 1 channel-group 0 timeslots 1-24

! Once a T1/E1 is created, LNM can be configured using 'span' CLI

Router (config-ctrlr-sts1)# t1 1 ?

channel-group Specify the timeslots to channel-group mapping for an T1

interface

clock Specify the clock source for a T1

fdl Specify the Facility Data Link for a T1

framing Specify the type of Framing on a T1

loopback Put the T1 line into loopback

shutdown Shut down a T1 interface (send AIS)

span Noise monitor for managing noisy T1 spans <Ð=

yellow Yellow Alarm Configuration for a T1

Example of a Syslog Message

The following is a sample output of a generated fault notification on a serial interface:

LNM-3- MINWARNEXCEED: Interface Serial7/0/0.1/1:0, noise exceeded above minor warning

threshold

.

Verification Example for Link Noise Monitoring

Example 3

shows the sample output when the LNM feature is configured. Use the show controllers t3

command to view the configuration information.

Example 3

Sample Output for Verifying LNM Configuration

Router# show controllers t3 7/0/0.1 lnm

Channel Monitoring type Thresholds (lcv/pcv/duration)

--------------------------------------------------------------------------------

1 minor-warn (syslog disabled) Set(154 /145 /10 ) Clear(154 /145 /10 )

remove (syslog disabled) Set(1544/320 /10 ) Clear(1544/320 /10 )

2 Channel not configured for E1/T1

3 Channel not configured for E1/T1

4 Channel not configured for E1/T1

5 minor-warn (syslog disabled) Set(154 /145 /10 ) Clear(154 /145 /10 )

6 Link Noise Monitoring is disabled

7 Channel not configured for E1/T1

8 Channel not configured for E1/T1

9 Channel not configured for E1/T1

10 Channel not configured for E1/T1

11 Channel not configured for E1/T1

12 Channel not configured for E1/T1

13 Channel not configured for E1/T1

14 Channel not configured for E1/T1

Advertising