General troubleshooting – Chauvet INTIMIDATOR 200 User Manual

Page 18

Advertising
background image




Page 18 of 22

Intimidator™ Scan LED 200 User Manual (Rev. 02a)

General Troubleshooting

Symptom

Possible Cause

Possible Action

Circuit breaker
or fuse keeps
blowing

· Excessive load on the circuit · Make sure that the total load

does not exceed 80% of the
breaker or fuse nominal
current

· Short circuit along the

power lines

· Check the power lines and

power cords

Product does not
power up

· No energy on power outlet

· Check power outlet
· Change to another outlet

· Loose or damaged power

cord

· Check the power cord

· Blown fuse

· Replace blown fuse with a

good one of the same type
and rating

· Internal problem

· Send product for repair

Fixture does not
respond to DMX

· Wrong starting address on

the fixture

· Set the correct starting

address on the fixture

· Use the right fader(s) on the

controller

· Wrong DMX personality on

the fixture

· Set the correct DMX

fixture’s personality

· Assign the faders

accordingly

· Wrong polarity setting on

the DMX controller

· Change the signal polarity

on the controller

· Loose or damaged DMX

cable

· Check the DMX cable

before the faulty unit

· Internal problem

· Send product for repair

Intermittent DMX
Problems

· Signal cables are not DMX

compatible

· Replace non DMX cables

with true DMX cables

· Interference with AC or

radio signals

· Keep DMX cables away

from AC wires or radio
equipment

· DMX cable too long

· Install an optically coupled

DMX amplifier right before
the fixture with intermittent
problems

· Too many fixtures

connected

· Install an optically coupled

DMX amplifier after unit #32

· Terminator not connected

· Install a terminator, as

indicated in the “DMX
Primer” section.

If you still experience problems after trying the above solutions, contact
CHAUVET® Technical Support.

Advertising