Setup, Ac power, Fuse replacement – Chauvet INTIMIDATOR 200 User Manual

Page 7: Etup

Advertising
background image




Intimidator™ Scan LED 200 User Manual (Rev. 02a)

Page 7 of 22

3.

S

ETUP

AC Power

This product has an auto-ranging power supply and it can work with an input voltage
range of 100~240 VAC, 50/60 Hz.

To determine the power requirements for a particular fixture, see the label affixed to
the back plate of the fixture or refer to the fixture’s specifications chart. A fixture’s
listed current rating indicates its average current draw under normal conditions.

Always connect this product to a protected circuit (circuit breaker or fuse),
making sure that it has an appropriate electrical ground to avoid the risk of
electrocution or fire.

Never connect this product to a rheostat (variable resistor) or dimmer circuit,
even if the rheostat or dimmer channel serves only as a 0 to 100% switch.

Fuse Replacement

Disconnect this product from the power outlet before replacing the fuse.

1) Disconnect the fixture from the power outlet.

2) With a Phillips #2 head screwdriver, unscrew the fuse

holder cap from its housing.

3) Remove the blown fuse and replace it with a good

fuse of the same type and rating (F 3.15 A @ 250 V).

4) Screw the fuse holder cap back in its place and

reconnect power.

Always replace a blown fuse with a good fuse of the same type and rating.