Motor Specifications and Electrical Requirements'

Power Supply and Motor Specifications

WARNING: To avoid electrical hazards, fire haz­
ards or damage to the tool, use proper circuit pro­
tection. Your tool is wired at the factory for
operation using the voltage shovim. Connect tool
to a power line with the appropriate voltage and a

IS-amp branch circuit. Use a 15-amp time delay

type fuse or circuit breaker. To avoid shock or fire,

it power cord is worn or cut, or damaged in any

way, have it replaced immediately.

The A -C m otor used in this tool is a reiay start, non-revsrs-

ibie type, having the follow ing specifications:

General Electrical Connections

DANGER: To avoid electrocution:

t. Use oniy identical replacement parts when ser­

vicing, Servicing should be performed by a
qualified service technician.

2

.

Do not use in rain or where floor is wet.

This tool is intended for indoor residential use
only.__________________________________

110-120 Volt, 60 Hz. Tool Information

N O TE: The plug supplied on your tool m ay not fit ihto the

outlet you are planning to use Your local electrical code

m ay

require

slightly

different

pow er

cord

plug

connec­

tions- If these differences exist refer to and m ake the

proper adjustm ents per your local code before your tool

is plugged in and turned on

In the event of a m alfunction or breakdow n, grounding

provides a path of least resistance for electric current to

reduce the risk of electric shock This tool is equipped

w ith an electric cord having an equipm ent-grounding con­

ductor and a grounding plug, as shown. The plug m ust

be

plugged

into

a

m atching

outlet

that

is

properly

installed and grounded in accordance w ith all local codes

and ordinances

D o not m odify the plug provided. If it will not fit the outlet,

have the proper outlet inslalled by a qualified siectrician

A tem porary adapter m ay be used to connect this plug to

a 2-prong outlet as show n if a properly grotinded three

prong

outlet

is

not

available.

This

tem porary

adapter

should

be

used

only

until

a

properly

grounded

three

prong outlet can be installed by a qualified electrician

The green colored rigid ear, lug or the like, extending

from

the

adapter

m ust

be

connected

to

a

perm anent

ground such as a properly grounded outlet box.

im proper

connection

of

the

equipm ent-grounding

con­

ductor can result in a risk of electric shock. The conduc­

tor with insulation having an outer surface that is green

w ith or w ithout yellow stripes is the equipm ent-grounding

conductor If repair or replacem ent of the electric cord or

plug is necessary, do not connect the equipm ent-ground­

ing conductor to a live term inal

R ated H P

1

Voltage

110-120

Am peres

11 5

H ertz (C ycles)

60

Phase

Single

R PM

3450

R otation of S haft

C ounterclockw ise

WARNING: Do not permit fingers to touch the ter­
minals of plug when installing or removing the
plug to or from the outiet.

If the grounding instructions are not com pletely under­

stood, or if you are in doubt as to w hether the too! is prop­

erly grounded check w ith a qualified electrician or service

personnel.

WARNING: If not properly grounded, this tool can
cause an electrical shock, particularly when used
in damp locations, in proximity to plumbing, or out
of doors, if an electrical shock occurs there is the
potential of a secondary hazard, such as your

hands contacting the sawblade.

Properly

Grounded

3-Prong Outlet

3-Prong Plug

Grounding

Prong

Grounding Lug

3-Prong ^

Make sure this

Is Connected

to a Known

Ground

2-Prong

Outlet

Adapter

N O TE: The adapter illustrated is for use oniy If you

already have a properly grounded 2-prong outlet

Advertising