CellarPro 1800XT-220V WARRANTY SERVICE, 11402 User Manual

Page 10

Advertising
background image

9

Alternatively, the front of the cooling unit can be supported by a shelf and a diagonal
brace. The shelf can be up to 13.25”(337mm) inches wide, and should be
positioned on the right side of the cooling unit so that it doesn’t restrict the exhaust

vent below the cooling unit, as follows:

Once the cooling unit is installed, all cracks and gaps between the cooling unit and
the cellar should be sealed. We provide butyl tape (shipped in the cavity of the
exhaust vent) for sealing these gaps. The butyl tape becomes pliable by rolling it in

your hands. Pay particular attention to the seams on the back of the cellar (top and
rear vent configurations) and the seams at the top of the cellar (top-vent
configuration).

Advertising
This manual is related to the following products: