Standard Protection Mechanisms

The cooling unit is programmed to shut down certain components to protect those
components, as well as the wine inside the cellar, under the following circumstances:

Scenario

What it means

What happens

P1 Alarm

Probe 1, which senses
the temperature inside
the cellar and controls

the on/off cycles of the
cooling unit, has failed

The cooling unit enters a timed
auto-cycle mode until Probe 1 is
repaired or replaced. In this mode,

the cooling unit will turn for 12
minutes and off for 8 minutes.

Optional Protection Mechanisms

CellarPro cooling systems can be programmed to turn off the compressor and
condenser fan in the event of an HA2 alarm, as described below. If you’d like to turn

on this protection mechanism, please call us toll-free at 877.726.8496

P3 > 60°C for more

than 2 hours

The condenser probe
is measuring

temperatures that are
too hot

The compressor and condenser
fan will turn off until the condenser
temperature falls below 60°C

Maintenance

The condenser coils at the back of the cooling unit will collect dust, dirt and lint over
time. It is critically important to clean the coils periodically. If the condenser coils
become clogged, the cooling unit will not have
proper airflow and its performance and longevity

will be compromised.

To clean the coils, simply vacuum or brush the
coils until all dust and lint have been removed. Do

not use compressed air to clean the coils because
it may force dirt particles into the cooling system
and cause serious damage to its internal
components.