CellarPro 1800XT-220V WARRANTY SERVICE, 11402 User Manual

Page 5

Advertising
background image

4

I . P r i o r t o I n s t a l l a t i o n


 Test the unit before installing it.

1. Remove the unit from the box. SAVE THE BOX AND PACKING MATERIALS.
2. Remove any materials that have been packed inside the exhaust cavity
3. Plug in the power cord and let the unit run on a hard, flat surface
4. Check to make sure that both fans (one at the top and one at the bottom of

the cooling unit) are spinning.

5. Check that the cooling unit is discharging cold air from the bottom (it should

be approximately 5.6°C colder than the temperature on the digital display)

 Make sure that the exhaust panel is installed in the correct position – it should

cover either the TOP or the REAR exhaust vent:

o

TOP VENT CONFIGURATION::
If the hot air will be discharged
through the TOP of the cellar,
install the exhaust panel on the

BACK of the cooling unit (as
shown in the Picture A). In this
configuration, the cavity on TOP
of the cooling unit is OPEN.



Picture

A

Top

Vent

Configuration

o

REAR VENT CONFIGURATION:

If the hot air will be discharged
through the REAR of the cellar,
use the exhaust panel to seal

the TOP of the cooling unit (as
shown in the Picture B). In this
configuration, the cavity at the
REAR of the CellarPro is OPEN.

Picture

B

Rear Vent Configuration

 Wait 24 hours before operating the cooling unit.

Advertising
This manual is related to the following products: