Model Dimensions

(mm)

W x D x H

Weight

(kg)

Operating

Amps

1800XT

457 x 419 x 267

27.2

2.0

 Cooling Capacity*

Estimated thermal loads for various size cellars, with various insulations, various
ambient temperatures and various cellar temperatures, are shown in the table below.

To figure out whether a CellarPro unit will work in your space, make sure that the
cooling unit’s BTUH for a given cellar temperature is equal or greater than the
thermal load shown. The bold numbers are within the capacity of both units. The
unbold numbers in black are within the capacity for the 1800XT 60Hz but not for the

1800XT 50Hz. The numbers in

red

are beyond the capacity of both cooling units.

Cellar Temp

12.8 °C

15.6 °C

BTUH

1800XT 220V/50Hz

1248

1353

BTUH

1800XT 230V/60Hz

1438

1543

Cellar Insulation –

All Walls, ceiling & floor*:

R-12

R-19

R-12

R-19

Cellar Size

Ambient Temp

23.9 °C

1034 946 889 814

2.83 m

3

29.4 °C

1180 1046 1038 920

35.0 °C

1331

1153 1195 1038

23.9 °C

1313

1186 1129 1020

5.66 m

3

29.4 °C

1538

1349

1353 1187

35.0 °C

1778 1525

1500 1373

23.9 °C

1594

1435 1371 1234

8.50 m

3

29.4 °C

1900 1562 1672

1463

35.0 °C

2225 1909 2003 1718