V9.14
condensate is present at the overflow, the switch may be turned “off”
to reduce unit energy consumption. For initial cellar pull down or in
high humidity environments, the switch should be set to “on”.
(4)
Power Selector Switch (Front/Rear): The unit is powered by installing
the provided plug cord in the front or rear of the unit. To use the front
receptacle, set switch to “Front” and plug in the cord at the front right
side of the unit (location #6). To use the rear receptacle, set to “Rear”
and plug in the cord at the rear of the unit (location #7).
(5)
Bottle Probe Jack (Bottle Probe): Plug in the remote bottle probe
(sold separately) to control the cellar by liquid temperature rather
than air temperature inside the cellar. Disconnecting the probe will
automatically return the control to air temperature. When using a
bottle probe, the Temperature Differential will need to be
adjusted to 1 degree as shown in the “Advanced Operation”
instructions below.
(6)
Grounded Power Receptacle: One receptacle is located on the front
right side (#6), and one on the rear (#7). Use the receptacle that
is most convenient for the installation. Enable the receptacle by
setting the power location switch (#4) to “Front” or “Rear”.
Control Panel Instructions
Digital Display
The temperature displayed on the control
indicates the real -time air temperature as
measured by Probe 1 (P1) located behind the
front grill of the cooling unit.