P l a c e m e n t

CellarPro 6200 and 8200 Series cooling units are designed to be installed THROUGH
THE WALL, so that the rear and the front of the cooling unit DO NOT SHARE THE SAME
AIR SPACE.

The rear of the cooling unit must be installed in a space that is at least as large as the
wine cellar unless the rear intake and exhaust are ducted. Both the front and the rear of
the cooling unit require a minimum clearance of 8 inches.

These units also can be placed completely INSIDE or OUTSIDE the cellar when used in
combination with our duct kits.

A m b i e nt E n v i r o nm e n t

6200VSi / 8200VSi

- designed for internal use only (ie sheltered from outdoor

weather), the rear of the unit can be exposed to temperature conditions ranging
from 40 to 115°F.

6200VSx / 8200VSx

– designed for external use, the rear of the unit can be

exposed to temperature conditions ranging from 40 to 115°F. Refer to the
Installation section for additional requirements for outdoor exposures.