 Ducted Installations – Rear Duct Kit

1. Ductwork may be attached to the discharge only, or to both the discharge and

return adapters.

2. The unit is capable of operating with 100 equivalent feet of total ductwork, or

50 equivalent feet for both the discharge and return ducting, for the rear and
the front of the cooling unit. Elbows or bends will reduce this length. Use a
duct sizing program to determine the total equivalent feet of a specific duct
routing design, or consult the manufacturer for recommendations.

3. The “High” fan speed setting is recommended for long duct runs and as

ambient temperatures rise. The “Low” fan speed should never be used in a
ducted application.