The cooling unit has both an audible notification and a visual alarm indicator
(shown in “red” on the control panel) that are activated when an alarm is triggered.
Please note: the temperature alarm (HA) is disabled during the first 23 hours of
operation after the cooling unit is plugged in and/or turned on.:

Alarm

Code

What it means

What to do

P1, P3

Probe Failure

Call CellarPro at 877.726.8496

HA

The temperature

inside the cellar is

too warm (above

70°F for more than 1

hour)

Check if the cellar has a leak

Check if door was left open

Lower the ambient temperatures

HA2 The

condenser

temperature is too high

(above 140°)

Check for appropriate installation, ventilation,

ambient conditions and cooling capacity

Replace/Clean clean the condenser filter

Check for obstructions to the intake and/or

exhaust vents

Increase fan speed to High.

Check that the condenser fan is operating

LA

The temperature inside

the cellar is too cold

(below 45°F)

Raise the ambient temperature

Raise the “Minimum Set Point”

LA2

The temperature at the

condenser coils

(outside the cabinet)

has dropped below the

alarm temperature

setting

Lower the alarm temperature setting:

1. Depress the “Set” and “Down” button for

three seconds until the display reads
“HY”

2. Depress the “Set” and “Down” button for

seven seconds until “PR2” flashes on the
display

3. Using the “Down” button, scroll until the

display reads “AL2”

4. Depress the “Set” button and lower the

alarm temperature setting to your desired
setting