CellarPro 4200VSX WINE COOLING UNIT (EXTERIOR), 1080 User Manual

Page 9

Advertising
background image


 

9

P o w e r R e q u i r e m e n t s

CellarPro cooling systems should be plugged into a dedicated non-GFI outlet
connected to a 15-amp circuit. The cooling unit uses approximately 11.5 (4200)
and 9.2 (3200) amps during its “on” cycle.

A number of variables, including the minimum set point, the temperature in the
ambient environment, the insulation of the cellar, and the thermal mass inside
the cellar, will affect the cooling unit’s runtime. It is normal for the cooling unit
to run up to 75 percent of the time in order to maintain proper conditions inside
the cellar.

Select a power receptacle (Front or Rear) and plug the provided power cord into
that receptacle. Plug the other end of the power cord into a dedicated 15 amp
circuit. A surge-protected circuit is recommended. Set the power selector
switch to energize the appropriate receptacle used (Front or Rear).

The power cord provided for the model 3200VSi and 4200VSi is approved for
indoor use only, while the power cord for model 3200VSx and 4200VSx may be
used both for indoor or outdoor applications.