RPM:

To select RPM Fuel Adjustment window, move the cursor right until it is under RPM and press “SEL”, Up

or Down Arrow. The following screen will appear:

.

RPM Min Max•

OFF 5560 7550

RPM OFF

Shows RPM mode is OFF.

5560

Min RPM threshold

7550

Max RPM threshold

Under RPM, press the up or down button to turn this mode ON or OFF.

Move the cursor right to adjust the Minimum RPM and the Maximum RPM. If RPM mode is ON, fuel
adjustment will activate only when RPM is between these values.


Press the “SEL” button to return to the Main Menu.

BTN:

To select the button mode, move the cursor right until it is under Btn. Press the up or down key to select

between the following five possible modes. The screen will change to the following:

OFF:

Description: Btn

Button Off :

OFF

This mode disables the handlebar button. Nitrous can still be activated with TPS or TPS plus RPM.

N2O:

Description: Btn

N2O + Fuel :

N2O

This mode adds nitrous and fuel when the button is pressed. When the button is pressed, nitrous will be
activated regardless of the TPS or RPM settings.

TUN:

Description: Btn

Fuel only :

TUN

When the handlebar button is pressed in TUN mode, only fuel is added. This is used to experiment
with fuel addition and subtraction while riding. Press the button at a certain RPM or under a certain
load to see whether your addition or subtraction is beneficial. This cannot be used in combination with
N2O operation. Be sure TPS and RPM triggering are OFF when using this feature. Also, set the fuel
number in the N2O menu to a low value such as two or minus two.

CAP:

Description: Btn

StatCapture:

CAP

In CAP mode, the handlebar button is used to capture current data. When pressed, the Stats Capture
screen will be displayed, but the data will not be frozen until the button is released. After a capture,
pressing the Right-Arrow button will erase the captured data and return to Run Mode.

ARM:

Description: Btn

On for N2O :

ARM

By using a pushbutton (momentary), toggle, rocker, or slide switch connected to the button input, the
nitrous system can be armed or disarmed. When the switch is closed the system is armed and ready.
Then, depending upon other configuration settings, either the TPS or TPS with RPM can activate the
nitrous system. When the switch is open, the system is disarmed so neither TPS nor RPM will result
in nitrous activation.

Nitrous activation idea: One way to use the button for nitrous activation and to have the RPM limiting feature
(to prevent hitting the rev-limiter), set Btn to ARM, TPS to ON (with a low threshold), and RPM to ON (with
desired Min/Max settings).


Press the Left or Right Arrow to return to the N2O menu or push the “SEL” button to return to the Main