Stats menus, 1 stats: run/capture, Run 35/40 – BoonDocker POLARIS: 11-12 PRO 800 Turbo 3D Tuning User Manual

Page 8: 5500 md, Line run, Line 5500, Run/capture mode, 2 stats: max-1, Max dcin/out clr, Max: 7600

Advertising
background image

BoonDocker Performance – 2379 Heyrend Way, Idaho Falls, ID 83402 – 208-542-4411 / 877-522-7805

www.boondockers.com – email:

[email protected]

– fax: 208-524-7381

Revised 1-20-11

Copyright © 2010 Boondocker

Page 8 of 14

5. Stats Menus

This Control Box has a new feature that allows real-time data to be displayed and captured. This feature can be useful for
tuning or for diagnostic purposes.

5.1 Stats: RUN/CAPTURE

Selecting Stats from the Main Menu will first display the following screen with real “Run-time” data (current
conditions):

Run 35/40

10.2N•

5500 MD

█ 010

1

st

line

Run

Run” indicates display is in Run mode, which displays current real-time data. If in capture

mode, “Cap” will be displayed.

35

Input duty cycle in percent (stock value)

40

Output duty cycle in percent (after change by Fuel Control Box)

10.2

Current Boost Pressure in PSI

N

If “N” displayed, Nitrous is on

2

nd

line

5500

Engine RPM

MD

Engine Load. LO, MD, or HI will be displayed.

These bars are a graphic display of LO, MD, or HI as shown below:

LO ,

MD

█,

HI

10

Current Fuel Adjustment

Run/Capture mode:

The Run/Capture mode will capture 9 frames of the realtime adjustments being made by the Control Box.

Left-Arrow button : Sets Capture Mode, “Cap” will be displayed and the current data will be frozen on the

display. The capture occurs on the display when the button is released (data will continue to
be captured if the button is held down). It will stay in capture mode (data will remain frozen)
until the Right-Arrow is pressed to return to Run mode or until the Control Box is re-
powered. If the Stats menu is re-entered before the engine is shut off and the box is in
Capture mode, the last captured data will be displayed.

Right-Arrow button: Clears capture mode (captured data will be lost!) and sets Run mode. “Run” will be

displayed and real-time data will be displayed. Note: The Handlebar Button Mode can also
be configured to Capture the Status screen.

Press SEL to go to the next screen: Stats: MAX-1.

5.2 Stats: MAX-1

The first MAX screen displays max RPM, Duty Cycle In from the sled’s ECU, and Duty Cycle Out to the injectors.

MAX DCIn/Out Clr

.

7600 35/45 Y

N

.

MAX: 7600

Max RPM

DCIn 35

Max Duty Cycle Input from sled’s ECU.

DCOut 45

Max Duty Cycle Output to the injectors.

These max values will be saved when the box is shut off so they will remain the next time this screen is displayed
even if the box is re-powered. Peak values or “spikes” are filtered by finding the average during a certain time-
window. Therefore, a maximum must be held for at least 1 second to be recorded and displayed properly.

Use the arrow keys to move the cursor between Y and N. Pressing SEL when the cursor is on Y will clear the max
values.

Pressing SEL when the cursor is on N takes you to the next screen: Stats: MAX-2.