Under TPS, press the Up or Down Arrow to toggle the TPS mode ON or OFF.

Move the cursor right to the 200 setting, then use the Up and Down Arrows to select the trigger level. This
number is set to near 200 at the factory. You can adjust it from 50 to 248. To choose your level, look at the
third Stats screen. (Press “SEL” to get to the Main Menu, then select Stats, and press “SEL” until the third
Stats screen appears – “N2O” is displayed in upper left-hand corner). Clear the current data by selecting
YES”. With the engine on a test stand, quickly press the throttle fully and release it. Note the number
under “MxTP” This is the maximum value your TPS will output. Let the engine idle, clear the Stats screen,
and note the MxTP number, which is the minimum TPS output. Choose a number close to but a little under
the maximum for full-throttle activation. If you choose a number too close to the maximum, it may
sometimes fail to trigger. If you choose a number too low, it may trigger when only moderate acceleration is
desired.

Press the “SEL” button to return to the Main Menu.

RPM:

To select rpm triggering, move the cursor right until it is under RPM and press “SEL”, Up or Down Arrow.

The following screen will appear:

.

RPM Min Max•

OFF 5050 7550

RPM OFF

Shows RPM mode is OFF.

Min 5050

If RPM mode is turned ON, nitrous will turn on above this RPM.

Max 7550

If RPM mode is turned ON, nitrous will turn off above this RPM.

Under RPM, press the up or down button to turn this mode ON or OFF.

Move the cursor right to adjust the Minimum RPM (nitrous will be on above this level) and the Maximum
RPM
(nitrous will turn off above this level).
Note: To use this mode, TPS must also be ON and the TPS trigger threshold set. Also, these limits will be
over-ridden if the button mode is set to N2O and the button is pressed.

Press the “SEL” button to return to the Main Menu.


BTN:

To select the button mode, move the cursor right until it is under Btn. Press the up or down key to select

between the following five possible modes. The screen will change to the following:

OFF:

Description: Btn

Button Off :

OFF

This mode disables the handlebar button.


N2O:

Description: Btn

N2O + Fuel :

N2O

This mode adds nitrous and fuel when the button is pressed. When the button is pressed, nitrous will be
activated regardless of the TPS or RPM settings.


TUN:

Description: Btn

Fuel only :

TUN

When the handlebar button is pressed in TUN mode, only fuel is added. This is used to experiment
with fuel addition and subtraction while riding. Press the button at a certain rpm or under a certain load
to see whether your addition or subtraction is beneficial. Use very low fuel numbers to experiment.
This cannot be used in combination with N2O operation. Be sure TPS and RPM triggering are OFF
when using this feature.


CAP:

Description: Btn

StatCapture:

CAP

In CAP mode, the handlebar button is used to capture current data. When pressed, the Stats Capture
screen will be displayed and the data will be frozen when the button is released. After a capture,
pressing the Right-Arrow button will erase the captured data and return to Run Mode.

Advertising