Stats menus – BoonDocker POLARIS: Non-turbo Control Box 2011-12 PRO RMK 800 User Manual
Page 7
BoonDocker Performance – 2379 Heyrend Way, Idaho Falls, ID 83402 – 208-542-4411 / 877-522-7805
www.boondockers.com – email:
– fax: 208-524-7381
Revised 1-20-11
Copyright © 2011 Boondocker
Page 7 of 17
5. Stats Menus
This Control Box has a feature that allows real-time data to be displayed and captured. This feature can be useful for
tuning or for diagnostic purposes.
5.1 Stats: RUN/CAPTURE
Selecting Stats from the Main Menu will first display the following screen with real “Run-time” data (current
conditions):
Run 35/38
F 6 █
5500 MD
█
█
█
N
Run
“Run” indicates display is in Run mode. If in capture mode, “Cap” will be displayed.
35
Input injector duty cycle in percent of cycle time on (this is the ECU injector signal)
38
Output injector duty cycle in percent of cycle time on (Fuel Control Box added 3% duty cycle)
F 6
Fuel adjustment by Control Box in ½% duty cycle. This is the fuel number for the current range.
5500
RPM (note, if the engine is shut off, the last recorded RPM may be displayed)
MD
Engine Load. LO, MD, or HI will be displayed.
█
█
█
These bars are a graphic display of LO, MD, or HI as shown below:
LO
MD
█
█
█
HI
█
█
█
█
█
█
N
Nitrous is on (also indicated by the black square above it)
Run/Capture mode:
Left-Arrow button : Sets Capture Mode, “Cap” will be displayed and the current data will be frozen on the
display. The capture occurs on the display when the button is released (data will continue to
be captured if the button is held down). It will stay in capture mode (data will remain frozen)
until the Right-Arrow is pressed to return to Run mode or until the Control Box is re-
powered. If the Stats menu is exited and re-entered before the engine is shut off and the box
is in Capture mode, the last captured data will still be displayed.
Right-Arrow button : Clears capture mode (captured data will be lost!) and sets Run mode. “Run” will be
displayed and real-time data will be displayed. Note: The Handlebar Button Mode can also
be configured to Capture the Status screen.
Press SEL to go to the next screen: Stats: MAX.
5.2 Stats: MAX
Any button press from the Run screen will go to the next Stats screen which is the Max screen, displaying max
RPM, Duty Cycle In from the sled’s ECU, and Duty Cycle Out to the injectors.
MAX DCIn/Out Clr
.
5500 35/45 Y
N
.
MAX: 5500
Max rpm
DCIn 35
Max Duty Cycle Input from sled’s ECU
DCOut 45
Max Duty Cycle Output to the injectors
Clr Y
N
Select “Y” to clear maximum values