16. Route the fan breaker and Control Panel Interface wires. You will need the wiring harness kit

P/N 76910601.


17. Connect the 5.5-inch blue wire labeled H to the lower left lug of the 15A circuit breaker.

18. Connect the 8-inch blue wire labeled I to the lower left lug of the upper 15A circuit breaker.

19. Connect the 6-inch brown wire labeled J to the top left lug of the bottom 15A circuit breaker.

20. Connect the 9-inch brown wire labeled K to the top left lug of the upper 15A circuit breaker.



21. Connect P/N 76950602 Control Panel Interface power supply cable to P9 on the Control Panel

Interface board – route behind the wires coming from the bottom of the DIN rail and between the top
and middle circuit breaker – connect to J1 and J2 on the power supply. Observe the locking tab on
the white connector. It needs to lock into place with the locking tab on the power supply connector.
The locking tab on the 3 pin connector at the top of the power supply should point down. The locking
tab on the 6 pin connector should point up.

Bottom
15A
breaker

K

I

J

H

Route
through here

P9