SECTION III-FABRICATION D - SILL WEEP NOTCHES

[FIG. 7]

[FIG. 8]

PAGE 11

END OF

SILL

NOTCH LEGS

AT EACH END

INTERIOR

END OF

SILL

TOP OF

SILL

EXTERIOR

To evacuate water from the system, weep notches must be placed at
the ends of each sill. This notch will manifest itself as a 1/8" X 1" notch

at each end of the sill, joining the vertical at the exterior face of the sill.

The notch also must remove the two extended legs in the middle

portion of the sill. These legs must be removed at the same height as

the face notch and requires that more material be removed. This

material removal will not be seen because it is under the sill and is

covered by the subsill. Refer to figures 7 and 8 below for notching

layout.

4475

SILL

ENSURE THAT THE EXTERIOR NOTCH IS CLEAN

AND UNIFORM FOR GOOD WATER FLOW, AND TO

MAKE THE NOTCH AS UNOBTRUSIVE AS
POSSIBLE WHEN VIEWED FROM THE EXTERIOR.