A. SCREW SPLINE

SECTION VIII-FRAME INSTALLATION

[FIG. 32]

[FIG. 31]

PAGE 25

CLEAN OFF

EXCESS SEALANT

795
SEALANT

NO SEALANT HERE

STEP 1) APPLYING SEALANT TO SUBSILL FOR

FRAME INSTALLATION

795

SEALANT

Ensure that enough 795 has been applied to seal the areas shown in

figure 32 below. After the frame has been installed, wipe off all

excess sealant that squeezes out.
795 sealant should only be applied to the subsill immediately prior to

the installation of the frame modules.

Apply 795 or equivalent silicone type sealant to the areas shown in
figure 31 below.

Do not apply sealant to the sill anchor leg receptor area. Excessive

sealant at this area may cause the system to lift up above the subsill
and not seat correctly.