5XP SLIDING GLASS DOOR INSTALLATION INSTRUCTIONS

B. Sill Starter Installation


1. Determine the cut length (cut length = [overall F.D. + 1/8”], unless shown otherwise) of the

sill starter and cut to length. Adhere H10F gasket to the FE71 end dam and attach to 14G0
sill starter with SLQ9 (#10-16 x 1” PL-PH-SMS 410 A-pt MG) screws. This will need to be
done to both sides of the sill starter. Note: 14B4 sill starter, when supplied, will have FE72
end dam wrap underneath the sill starter. (See Fig. E)
























2. Fasten down the sill starter with job specified anchors. (See Section I. D.) There is a groove

in the sill starter to locate the drill bit. Drill through the sill starter, at the groove, and continue
to drill through the support leg underneath the main web of the sill starter. 14G0 sill starter is
shown; 14B4 sill starter is similar. All blocking and shims will be high strength plastic or non-
corrosive materials, Not by EFCO. (See Fig. F)


SLQ9
SCREWS

FE71 END DAM

H10F GASKET

Fig. E

Fig. F

Groove location in this area

where anchor head is shown.

FE72 END DAM

14B4 SILL
STARTER

14G0 SILL
STARTER