5XP SLIDING GLASS DOOR INSTALLATION INSTRUCTIONS


7. Once the door is properly shimmed and anchors are fastened per anchorage specified,

apply sealant over the anchor heads. (See Fig. M) After the sealant has been properly
applied and tooled over the anchor heads, apply sealant over the access holes. (See Fig. N)
Sealant over the clear holes can be accomplished by stuffing backer rod or like material into
the clear hole cavity and sealing over.









8. Seal all exposed perimeter joints between structure and door frame perimeters with a

skinning, non-hardening type of sealant. Refer to the approved shop drawings for joint
design. (See Figs. P and Q)


9. Seal all frame to frame and frame to accessory (subframe, panning, mullions) joints with

compatible silicone sealant. Refer to the approved shop drawings for joint design. (See
Figs. P and Q)











Note: All perimeter sealants must be continuous with one another and tooled with no voids.

Fig. M

Fig. N

Note: Ensure that the perimeter shims do not interfere with the exterior and interior
perimeter sealant joints that are to be in accordance with the sealant manufacturer’s
recommendations.