Install the 10/100 Ethernet Filter

2. Turn the top of the strain relief until the strain relief is loosened from the power

cord.

3. Remove the terminal ring and spade lugs from filter.

4. Remove the cord from the filter.

5. Replace with a Schuko plug and cord.

6. Using the provided spare terminal ring and spade lugs, wire the ground wire and

power wires, as required.

7. Tighten the strain relief around the power cord, and replace the access cover.