Common Diagnostic Techniques

www.ets-lindgren.com

D

IFFERENTIAL

M

ODE

T

ECHNIQUES

Some traditional differential mode techniques

do not work in common mode situations

When differential mode solutions are applied to a common mode problem; many

of the techniques will prove ineffective. For example:

Reducing circuit loop area: The radiating signal is on the signal and

return path, so this will be ineffective. Using twisted pair wires or coax

will yield little in the way of signal reduction.